The constant temperature and humidity laboratory is used for testing the performance indicators of aerospace products, information and electronic instruments, materials, electricians, electronic products and various electronic components in high and low temperature or hot and humid environment.
 
Technical parameters of constant temperature and humidity laboratory
Internal dimensions: 100 x 100 x 80 (W * H * D) CM
External dimensions: 150 x 186 x 137 (W * H * D) CM
Temperature regulation and humidity control: balanced temperature regulation and humidity control (BTHC) PID intelligent adjustment.
Temperature range: 0 C, -20 C, -40 C, -60 C, -70 C, ~150 C, 20%-98%R.H
Temperature and humidity control accuracy: + 0.2 C; + 2.5%RH
Uniformity in temperature and humidity box: + 0.5 C ~ + 0.2 C; + 4.0%RH
Controller resolution accuracy: + 0.01% C; + 1%R.H
Heating rate: greater than or equal to 2.5 degrees C/min
Cooling rate: average 1 degree C/min
 
Material and configuration of constant temperature and humidity laboratory room
Inner material: SUS#304 mirror stainless steel plate.
Case material: high density cold rolled steel sheet, nano sprayed plastic or SUS#304 stainless steel.
Insulation material: super fine glass wool + polyurethane foam.
Refrigeration mode: mechanical two element refrigeration mode.
Refrigerator: fully enclosed (France Taikang or German Valley) compressor
Refrigerant: R23/ R404A
Condensation mode: air cooling or water cooling.
Heater: Ni Cr alloy stainless tube heater
Humidifier: stainless steel humidifier
Blower: centrifugal fan
Airflow mode: Broadband forced air circulation (up and down)
Operation interface: LCD touch screen, switching between Chinese and English.
Operation mode: constant operation and program operation
Program memory capacity: 120 sets of programmable, each program * Large 100 (segment)
Set target range: temperature: -100 C +300 C humidity: 99.9%R.H
Resolution: temperature: 0.1 C humidity: 0.1%R.H
Input: PT100 or T type thermocouple
Control mode: PID control
Communication function: RS-232 interface
Print function: Henghe 6 point logger (optional)
Water supply mode: circulating water supply
Water supply box: built-in hand pull type (30Kg capacity)
Water quality: resistivity > 500 Omega.M
 
Constant temperature and humidity laboratory conform to standard
Technical conditions for high and low temperature test box
Technical requirements for heat exchanger box
A test method for high temperature
Test method for B low temperature test
Ca test method for constant humidity and heat
Db test

Related products

  • What are the requirements for water in the constant temperature and humidity test chamber? Release time: 2019-07-17

    Abstract: environmental humidity and tap water regulation are very important in constant temperature and humidity test chamber. If the water body is unclean, every water body passes the test. Will it be harmful if the normal drinking water is used? ...

  • What are the vacuum glove box accessories in the production of lithium batteries? Release time: 2019-04-22

    What are the details of the vacuum glove box accessories during the production of lithium batteries? In recent years, with the rise of China's lithium battery manufacturing industry, many lithium battery manufacturers have made the domestic lithium battery market unbalanced.

  • How to choose glove box Release time: 2019-04-06

    In our vacuum environment experiment or inert gas experiment, we often encounter the problem of how to choose the glove box. According to the experience of our company engineers, we can generally carry out the glove box through the following conditions.

  • The glove box is broken. How can we solve it? Release time: 2019-03-26

    The cause of oxygen content in glove box is greater than 200ppm: new box debugging or incorrect operation. Method: stop circulation, open cleaning, clean below 100ppm, open cycle. The glove box screen shows that the main valve pressure is less than 0.4MPa or main valve.

  • What kinds of gloves are there? Release time: 2019-03-19

    Glove box includes vacuum glove box, plexiglass glove box, purifying glove box. The glove box in the glove box is actually the concept of glove box introduced just now when it came to China.

  • How to distinguish glove box from good or bad? Release time: 2019-03-19

    The concept and equipment of glove box equipment have been introduced to our country for more than 10 years. The principle and manufacturing process are constantly being digested by domestic glove box manufacturers, and the products of domestic glove box manufacturers have gradually matured, but...


Please fill out your needs and contact information, so that you can contact customer service conveniently.

Order products:
Your name:
Contact information:
Contact mailbox:
Location:
Remarks:
    
Contact us
 Contact us Tel: (86) 021-51061816021-51061336
Fax: (86) 021-33321187
Address: No. 2216 Jingao Road, Jinqiao Industrial Park, Pudong New Area, Shanghai.
Zip code: 200940
[upward]  
Online Service

Online consultation

Online consultation

Online consultation

Telephone:
021-5106181651061336
 QR code

Focus on WeChat

北斗棋牌全部版本 567彩票 下载 乐彩网17500双色球出球顺序 3d172前后关系 下载星云娱乐斗地主 2019斗地主怎么创建房间 乐彩3d论坛手机17500 中彩网投注为什么不花钱 S中彩票妙招 5933cc彩票在线